SPECIFICATIONS

Valve
Size
Model
No.
Flow
Coefficient
Cv
Conductive
Heat Leak
BTU/HR
Cool Down
Weight LBS
½” 500 6.6 6.4 2.6
1" 1000 14 9.2 3.3
1½” 1500 34 10.0 6.1
2" 2000 50 14.3 9.0

OPTIONAL EQUIPMENT

Valve Trims Quick Opening (Q)
Linear (L)
Equal Percentage (E)
(see above)
Actuators Fisher Pneumatic Spring & Diaphragm Type Standard (Other Styles and Types Available)
Accessories: Positioners
I/P Converters
Limit Switches
Other Available
Valve End Connections Tube Socket (ST)
Pipe Socket (SP)
Tube Stub (T)
Pipe Stub (P)
Stub Extensions with Flanges (Custom)
Vacuum Jacketed
Super Insulation
Multilayer Insulation with Welded 304 Stainless Steel Jacket

ORDERING INFORMATION

Valve Size CV-0500 = ½”
CV-1000 = 1"
CV-1500 = 1½”
CV-2000 = 2"
Series A = Non Bellows
H = Bellows
Gas Service AR = Argon
HE = Helium
HY = Hydrogen
NG = Natural Gas
NT = Nitrogen
OX = Oxygen
Jacket O = Non Jacketed
V = Jacketed
End Connections T = Tube Stub
P = Pipe Stub, Schedule 5
ST = Socket, Tube
SP = Socket, Pipe
C = Custom (factory)
Valve Flow
Control Plug
Q = Quick Opening
L = Linear
E = Equal Percent
Actuator M = Manual
A = Actuated

ORDERING EXAMPLE

Model No. :
CV-1000-H-HY-V-P-L-M

Description:
1" Cryogenic Globe Valve, Bellows Design, Hydrogen Service, Vacuum
Jacketed, 1" Schedule Pipe Stubs, Linear Flow Plug, Manual.